Hematocrit (PCV HCT)
Department: Hematology
Test Synonym(s): LAB289, PCV, Hematocrit, Packed cell volume, HCT
CPT Codes: 85014
Methodology: Sysmex
Reference Range: Male: 41 - 49%, Female: 36 - 43%
Tube Type: Lavender top (EDTA)
Specimen: Whole blood
Pediatric Requirements: Lavender top (EDTA) tube (to fill line only) or 0.5 mL EDTA microtainer
Volume: 2 mL
Minimum Volume: 500uL
Temperature: Room temperature or refrigerated
Stability: 24 hours if refrigerated
Reasons for Rejection: QNS, clotted, specimen age
Days Performed: Daily
Times Performed: Continuous
TAT: Stat: 1 hour
Special Instructions: Deliver to the lab within 4 hours. Draw 2 mL to fill line only or may draw EDTA microtainer.
Search Help
Search Options for the Test Directory:
1. Enter the test name in the Keyword search field.
Hint: You can also enter any part of the test name to expand the search.
(Example: you can type "west" or "sed" or "rate" to find Westergren Sedimentation Rate)
2. Enter the Vanderbilt Test Code, if known.
3. Choose one of the letter boxes to display a list of all test names and keywords starting with that letter.
If you are unable to find a test in our directory, please contact VPLS at
1-800-551-5227 or e-mail emily.k.thompson@vumc.org.